The majority of users, on the other hand, think and operate in volume terms. Mass & volumetric flow standardsįollowing the example above, you would consider that mass flow should be stated in weight units like g/h, mg/s, and so on. When we move the piston halfway to the bottom of the cylinder, the volume of air contained is only 1/2 liters, the pressure is increased to around 2 bar, but the mass remains the same, 1.293g, as nothing has been added or removed from the cylinder. This volume of air weights 1.293g, which equals the mass of the air enclosed to the cylinder. Secondly, assume that this cylinder holds 1.0 litre of air at ambient pressure (1 atm) and 0 oC temperature. Wondering what is mass flow and what is volumetric flow? Let’s see it this way:Īssume you have a 1.0 litre cylinder with a movable piston of negligible weight that closes it. This unit looks like a volumetric flow unit, but in truth expresses mass flow. Contact Omega engineering for details.ES Systems’ thermal gas mass flow meters measure flow in ln/min. Wetted Parts: 303 & 302 Stainless Steel, FKM Heat Cured Silicone Rubber, Glass Reinforced Polyphenylene Sulfide, Heat Cured Epoxy, Aluminum, Gold, Silicon, Glass. Supply Current: 35 mA typical current draw 100 mA available supply recommended Supply Voltage: 7 to 30 Vdc (15 to 30 Vdc for 4 to 20 mA output) The primary trade-off for response time is signal noise A variable register allows response time to be field adjustable to a certain extent via RS232 communications. Response Time: 10 ms typical default response time for 63.2% of a step change. These flowmeters are also available in a portable version for use in the field (-B models). It is also possible to multi-drop up to 26 units on the same serial connection to a distance of 125'. Volumetric flow, mass flow, or absolute pressure, and temperature can be viewed or recorded through the RS232 connection. The gas select feature can be adjusted from the front of the keypad or via RS232 communications. Standard units include a 0 to 5 V output (4 to 20 mA optional) and RS232 communications. This standardized flow rate is commonly called the mass flow rate and is reported in units such as standard cubic feet per minute (SCFM) or standard liters per minute (SLM). Separate absolute temperature and pressure sensors are incorporated and correct the volumetric flow rate to a set of standard conditions. This, along with the viscosity of the gas, is used to accurately determine the volumetri flow rate. Inside this region, the Poiseuille equation dictates that the volumetric flow rate be linearly related to the pressure drop along a fixed distance of the LFE. A laminar flow element (LFD) insdie the meter forces the gas into laminar (streamlined) flow. The FMA-1600A Series mass and volumetric Omega's flow meters use the principle of differential pressure within a laminar flow field to determine the mass flow rate.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |